• Show Sidebar

There are 294 products.

Active filters

  • Categories: Bios Chip Programming
  • Categories: Laptop used parts, scrap parts
  • Categories: Multimeter, Test Tools
  • Availability: In stock

ZOTEK ZT111 Mini 9999 Counts Digital Multimeter ACDC Voltage Current Tester

Login to Download: * User Manual

Description:

This digital multimeter is designed to offer users better performance and higher safety rating.

550V over-load protection and unique structural design make it new type of multimeter with high performance/price ratio and a best choice for the laboratory,factories, radio enthusiasts.

Features:

9999 Counts & Multi-function:Can display 9999 counts and measure AC/DC Voltage,AC/DC Current,Resistance,Capacitance,Frequency,Duty Cycle,Diode,Continuity Testing,NCV and Temperature.

Portable Design:There is a back bracket for supporting multimeter, and also can collect test probe for your convenience.

Wide range of applications:It's perfect home tools for the laboratory, factories, radio enthusiasts.

Easy to Use & Clear to Read:With large LCD backlight display, convenient to use and read in a dark environment.

Auto Power off:15 minutes after the rotary switch is opened,the meter automatically enters the sleep state to reduce energy consumption.

Specifications:

Brand name:ZOTEK

Model number:ZT111

Material:ABS

Color:Gray&Red

Sample rate: 3 times per second

Display:9999 Counts

Range:Auto/Manual

Ture RMS:Yes

Date hold:Yes

Low voltage indication:Yes

Auto power off:Yes

Over range indication:OL

Backlight:Yes

Diode test:Yes

Continuity test:Yes

NCV test:Yes

Main measurements:AC/DC Voltage, AC/DC Current, Resistance,Capacitance,Frequency,Duty Cycle,Diode,Continuity Testing,NCV and Temperature.

DC volts:9.999mV/99.99mV(0.5%+3),999.9mV/9.999V/99.99V/999.9V(0.5%+3)

AC volts:999.9mV/9.999V/99.99V/750V(1.0%+3),9.999mV/99.99mV(1.0%+3)

DC current:999.9mA/9.999A(1.0%+3),99.99A/999.9A(0.8%+3)

AC current:999.9mA/9.999A(1.2%+3),99.99A/999.9A(1.0%+3)

Resistance:99.99/999.9/9.999k/99.99k/999.9KO(0.5%+3),9.999/99.99MO(1.5%+3)

Capacitance:9.999nF(5.0%+20)

99.99nF/999.9nF/9.999F/99.99F(2.0%+5)

9.999mF(5.0%+5)

Frequency:99.99/999.9/9.999k/99.99k/999.9k/9.999MHz (0.1% + 2)

Duty Cycle:1%~99%( 0.1% + 2)

Temperature:(-20~1000)?(2.5%+5)

(-4~1832)?(2.5%+5)

Working environment: 0~40C,relative humidity<75%

Supply power:1.5V AAA battery * 2 (not included)

Product Weight:127g

Product Size:125mm * 65mm * 24 mm

Package Size:16 * 9.7 * 4.5cm / 6.3 * 3.8 * 1.8in

Package Weight:259g/0.57lb

Package List:

1 x Digital Multimeter

2 x Test Leads

1 x Temperature Test Cable

1 x English Manual

1 x Cloth bag

CH003099
€23.50

ZOTEK ZT111 Mini 9999 Counts Digital Multimeter AC/DC Voltage Current Tester

A1304 EMC 2253 Bios Chip EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9300 MB543LLA

PO000038
€18.00 €22.50

A1304 EMC 2253 Bios EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9300 MB543LL/A

0300V OnOff switch SmartFit Voltage All Size LED LCD TV Laptop Backlight Tester Tool Lamp Beads Test

0-300V Smart-Fit Voltage Backlight Tester Tool for All Size LED LCD TV Laptop Detect Repair

LED LCD TV backlight problems are always increasingly common. As we know, slight tension Change can have a great impact on TV function. To have a useful tool which is as LED LCD Backlight tester. Using this tool, you can use the LED LCD screen backlight problem quickly. With the function, operating voltage, you can use the exact problem. If there is something wrong with LED light group, you can use it or replace the bad LED beads.

Product description:

Model No.: DLV300

Input voltage: 85-265 V international general

Output voltage: 0-300 V

Notice:

Please, if you are used to the LED lamps finished, unplug the power supply before!

Because it is likely to form a loop, which in Abnormal test!

Additional application:

The capacitance voltage

The voltage regulator

worth 3 lamp drive voltage test!

Examination skills:

Plug IN POWER, it can be used after 5 to 10 seconds (first time, the machine needs to warm up!).

Soft Start mode make the backlight brighter always slow.

No burning, if you can not make the "+" and "-", do not connect the probes to the LED will be tested for a long time.

Open ciruit protection: Do not touch the output terminal of probes for a long time. It is safe for Touch the probes in the shortest time.

Double isolate design makes our testers safety with high strength and flame retardant materials.

Safe / smart / precise / highly efficient

Double isolated safe protection no burning, no electric shock, voltage and current intellgent setting,

High brightness disassemble no need.

Single LED light bar backlight check:

make sure the anode and acthode.

connect the probes to the anode and the cathode.

light up the single LED light bar backlight.

light up the double LED light bar backlight.

Package include:

1x Tester

2X gold plated pin

1x Power Cable

Attention:

The more quantity, the lower price. Please contact us for details.

CH003169
€14.92

0-300V On-Off switch Smart-Fit Voltage All Size LED LCD TV Laptop Backlight Tester Tool Lamp Beads Test

A1304 EMC 2253 Bios Chip EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9400 MB940LLA

PO000039
€18.00 €22.50

A1304 EMC 2253 Bios EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9400 MB940LL/A

DY302 2500V 20G ohm Digital Insulation Resistance Tester Megger Megohmmeter

I.Specification:

* Three test voltage , the measured insulation resistance 20G

* 600V AC voltage measurement

* Low resistance buzzer

* Data hold , auto range

* Low battery warning

* Completion and testing lines , heavy suitcase and section six 1.5V AA batteries

Model DY30 - 1 DY30 - 2

The test voltage 250/500/1000V 500/1000/2500V

Resistance 0 ~ 2000M? (3% +5) 0 ~ 20G? (3% +5)

AC V 700V (2% +5) 700V (2% +5)

Auto range Yes

Function symbols are displayed Yes

Data Retention Yes

Low resistance buzzer Yes

Low battery warning Yes

LCD Max. Count 1999

Power AA1.5Vx6 (Not included)

Size 150 * 100 * 70 mm

NW About . 680 g

CH003175
€53.33

DY30-2 2500V 20G ohm Digital Insulation Resistance Tester Megger Megohmmeter

A1304 EMC 2334 Bios Chip EFI Firmware 820-2375 Mid2009 Core 2 Duo SL9400 MC233LLA

PO000040
€18.00 €22.50

A1304 EMC 2334 Bios EFI Firmware 820-2375 Mid-2009 Core 2 Duo SL9400 MC233LL/A

A1304 EMC 2334 Bios Chip EFI Firmware 820-2375 Mid2009 Core 2 Duo SL9600 MC234LLA

PO000041
€18.00 €22.50

A1304 EMC 2334 Bios EFI Firmware 820-2375 Mid-2009 Core 2 Duo SL9600 MC234LL/A

A1370 EMC 2393 Bios Chip EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9400 MC505LLA

PO000042
€18.00 €22.50

A1370 EMC 2393 Bios EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9400 MC505LL/A

A1370 EMC 2393 Bios Chip EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9600 MC906LLA

PO000043
€18.00 €22.50

A1370 EMC 2393 Bios EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9600 MC906LL/A

Hantek DSO4202C Digital Oscilloscope 2CH 200MHz Bandwidth 1GSas

Features:

1.2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger;

2.The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously;

3.Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform;

4.Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions;

5.Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative;

6.Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle 7.wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.

8.Support SD card, VGA function (optional);

9.Integrated USB Host, Support USB disk storage, USB interface/SD card system update.

Specifications:

Model DSO4202C

Oscilloscope

Sample Rate Sampling Rate Range: 1GSa/s

Equivalent Sample Rate: 25GSa/s

Acquisition Modes

Normal Normal data only

Peak Detect High-frequency and randon glith capture

Average Wavefom Average, selectable 4,8,16,32,64,128

Inputs

Inputs Coupling AC, DC, GND

Inpits Impendance 1MO2% ?20pF3pF

Probe Attenuation 1X, 10X

Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X

Maximum Input Voltage CAT I and CAT II: 300VRMS (10)

CAT III: 150VRMS(1);

Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Horizontal

Sample Rate Range 1GS/s

Waveform Interpolation (sin x)/x

Record Length 40K

SEC/DIV Range 2ns/div to 40s/div 4ns/div to 40s/div

Sample Rate and 50ppm(at over any =1ms time interval)

Delay Time Accuracy

Position Range 2ns/div to 10ns/div; 20ns/div to 80us/div; (-8div x s/div) to 40ms;

(-4div x s/div) to 20ms; 200us/div to 40s/div; (-8div x s/div) to 400s

Delta Time Measurement Accuracy

(Full Bandwidth) Single-shot, Normal mode: (1 sample interval +100ppm reading + 0.6ns);

>16 averages: (1 sample interval + 100ppm reading + 0.4ns);

Sample interval = s/div 200

Vertical

Vertical Resolution 8-bit resolution, all channel sampled simultaneously

Position Range 2mV/div to 10V/div

Bandwidth 200MHz 100MHz 70MHz

Rise Time at BNC( typical) 1.8ns 3.5ns 5ns

Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, 400mV; 50mV/div to 200mV/div, 1V

500mV/div to 2V/div, 40V; 5V/div, 50V

Math +, -, *, /, FFT

FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;

1024 sample point

Bandwidth Limit 20MHz

Low Frequency Response (-3db) =10Hz at BNC

DC Gain Accuracy 3% for Normal or Average acquisition mode, 5V/div to 10mV/div;

4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy,

Average Acquisition Mode When vertical displacement is zero, and N =16: (3% reading + 0.1div + 1mV) only 10mV/div or greater is selected;

When vertical displacement is not zero, and N=16: [3% (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of =16 waveforms acquired under same setup and ambient conditions

Trigger System

Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source CH1, CH2, EXT, EXT/5, AC Line

Trigger Modes Auto, Normal, Single

Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject

Trigger Sensitivity

(Edge Trigger Type) DC(CH1,CH2):

1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;

DC(EXT):

200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;

DC(EXT/5):

1V from DC to 100MHz;1.75V from 100MHz to 200MHz;

AC: Attenuates signals below 10Hz;

HF Reject: Attenuates signals above 80kHz;

LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

Trigger Level Range CH1/CH2: 8 divisions from center of screen;

EXT: 1.2V;

EXT/5:6V

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times =20ns CH1/CH2: 0.2div volts/div within 4 divisions from center of screen;

EXT: (6% of setting + 40mV);

EXT/5: (6% of setting + 200mV);

Set Level to 50%(typical) Operates with input signals =50Hz

Video Trigger

Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;

EXT/5: 2V

Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range 100ns ~ 10s

Pulse Width Trigger

Pulse Width Trigger Mode Trigger when (< , >, = , or ?); Positive pulse or Negative pulse

Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.

Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

Less than: The trigger point is the trailing edge.

Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range 20ns ~ 10s

Slope Trigger

Slope Trigger Mode Trigger when (< , > , = , or ? ); Positive slope or Negative slope

Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.

Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than the set slope.

Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range 20ns ~ 10s

Overtime Trigger

Over Time Mode Rising edge or Falling edge

Time Range 20ns ~ 10s

Alternative Trigger

Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter

Readout Resolution 6 digits

Accuracy (typical) 30ppm (including all frequency reference errors and 1 count errors)

Frequency Range AC coupled, from 4Hz minimum to rated bandwidth

Signal Source Pulse Width or Edge Trigger modes: all available trigger sources

The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.

Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.

Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.

Video Trigger mode: The Frequency Counter does not work.

Measure

Cursor Measurement Voltage difference between cursors: ?V

Time difference between cursors: ?T

Reciprocal of ?T in Hertz (1/?T)

Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,

+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,

Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,

FRF, FFR, LRR, LRF, LFR, LFF

Signal Source Mode

Waveform Impedance DC-25MHz

Sample Rate 200MHzDDS

Output Waveform Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC

Frequency Resolution 0.1%

Waveform Depth 2KSa

Vertical Resolution 12bit

Frequency Stability <30ppm

Waveform Range -3.5V~+3.5V

Output Impedance 50O

Output Current 50mA Ipeak=100mA

System BW 25M

Harmonic Distortion -50dBc(1KHz),-40dBc(10KHz)

General Features

Display

Display Type 7 inch 64K color TFT (diagonal liquid crystal)

Display Resolution 800 horizontal by 480 vertical pixels

Display Contrast Adjustable (16 gears) with the progress bar

Probe Compensator Output

Output Voltage( typical) About 5Vpp into =1MO load

Frequency(typical) 1kHz

Power Supply

Supply Voltage 100-120VACRMS(10%), 45Hz to 440Hz, CAT?

120-240VACRMS(10%), 45Hz to 66Hz, CAT?

Power Consumption <30W

Fuse 2A, T rating, 250V

Environmental

Temperature Operating: 32? to 122? (0? to 50?);

Nonoperating: -40? to 159.8? (-40? to +71?)

Cooling Method Convection

Humidity +104? or below (+40? or below): =90% relative humidity;

106? to 122? (+41? to 50?): =60% relative humidity

Altitude Operating: Below 3,000m (10,000 feet);

Nonoperaring: Below 15,000m(50,000 feet)

Mechanical

Size Length 385mm, Width 200mm, Height 245mm

Weight 3.5KG(with Packing); 2.08KG(without Packing)

Package List:

1 x Digital Storage Oscilloscope

2 x Probes

1 x Oscilloscope Power line

1 x Hantek data CD

1 x USB line

1 x Manufacturer Certificate

CH003252
€364.26

Hantek DSO4202C Digital Oscilloscope 2CH 200MHz Bandwidth 1GSa/s

ZOTEK ZT111 Mini 9999 Counts Digital Multimeter ACDC Voltage Current Tester

Login to Download: * User Manual

Description:

This digital multimeter is designed to offer users better performance and higher safety rating.

550V over-load protection and unique structural design make it new type of multimeter with high performance/price ratio and a best choice for the laboratory,factories, radio enthusiasts.

Features:

9999 Counts & Multi-function:Can display 9999 counts and measure AC/DC Voltage,AC/DC Current,Resistance,Capacitance,Frequency,Duty Cycle,Diode,Continuity Testing,NCV and Temperature.

Portable Design:There is a back bracket for supporting multimeter, and also can collect test probe for your convenience.

Wide range of applications:It's perfect home tools for the laboratory, factories, radio enthusiasts.

Easy to Use & Clear to Read:With large LCD backlight display, convenient to use and read in a dark environment.

Auto Power off:15 minutes after the rotary switch is opened,the meter automatically enters the sleep state to reduce energy consumption.

Specifications:

Brand name:ZOTEK

Model number:ZT111

Material:ABS

Color:Gray&Red

Sample rate: 3 times per second

Display:9999 Counts

Range:Auto/Manual

Ture RMS:Yes

Date hold:Yes

Low voltage indication:Yes

Auto power off:Yes

Over range indication:OL

Backlight:Yes

Diode test:Yes

Continuity test:Yes

NCV test:Yes

Main measurements:AC/DC Voltage, AC/DC Current, Resistance,Capacitance,Frequency,Duty Cycle,Diode,Continuity Testing,NCV and Temperature.

DC volts:9.999mV/99.99mV(0.5%+3),999.9mV/9.999V/99.99V/999.9V(0.5%+3)

AC volts:999.9mV/9.999V/99.99V/750V(1.0%+3),9.999mV/99.99mV(1.0%+3)

DC current:999.9mA/9.999A(1.0%+3),99.99A/999.9A(0.8%+3)

AC current:999.9mA/9.999A(1.2%+3),99.99A/999.9A(1.0%+3)

Resistance:99.99/999.9/9.999k/99.99k/999.9KO(0.5%+3),9.999/99.99MO(1.5%+3)

Capacitance:9.999nF(5.0%+20)

99.99nF/999.9nF/9.999F/99.99F(2.0%+5)

9.999mF(5.0%+5)

Frequency:99.99/999.9/9.999k/99.99k/999.9k/9.999MHz (0.1% + 2)

Duty Cycle:1%~99%( 0.1% + 2)

Temperature:(-20~1000)?(2.5%+5)

(-4~1832)?(2.5%+5)

Working environment: 0~40C,relative humidity<75%

Supply power:1.5V AAA battery * 2 (not included)

Product Weight:127g

Product Size:125mm * 65mm * 24 mm

Package Size:16 * 9.7 * 4.5cm / 6.3 * 3.8 * 1.8in

Package Weight:259g/0.57lb

Package List:

1 x Digital Multimeter

2 x Test Leads

1 x Temperature Test Cable

1 x English Manual

1 x Cloth bag

CH003099
€23.50

ZOTEK ZT111 Mini 9999 Counts Digital Multimeter AC/DC Voltage Current Tester

  • -20%

A1304 EMC 2253 Bios Chip EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9300 MB543LLA

PO000038
€18.00 €22.50

A1304 EMC 2253 Bios EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9300 MB543LL/A

0300V OnOff switch SmartFit Voltage All Size LED LCD TV Laptop Backlight Tester Tool Lamp Beads Test

0-300V Smart-Fit Voltage Backlight Tester Tool for All Size LED LCD TV Laptop Detect Repair

LED LCD TV backlight problems are always increasingly common. As we know, slight tension Change can have a great impact on TV function. To have a useful tool which is as LED LCD Backlight tester. Using this tool, you can use the LED LCD screen backlight problem quickly. With the function, operating voltage, you can use the exact problem. If there is something wrong with LED light group, you can use it or replace the bad LED beads.

Product description:

Model No.: DLV300

Input voltage: 85-265 V international general

Output voltage: 0-300 V

Notice:

Please, if you are used to the LED lamps finished, unplug the power supply before!

Because it is likely to form a loop, which in Abnormal test!

Additional application:

The capacitance voltage

The voltage regulator

worth 3 lamp drive voltage test!

Examination skills:

Plug IN POWER, it can be used after 5 to 10 seconds (first time, the machine needs to warm up!).

Soft Start mode make the backlight brighter always slow.

No burning, if you can not make the "+" and "-", do not connect the probes to the LED will be tested for a long time.

Open ciruit protection: Do not touch the output terminal of probes for a long time. It is safe for Touch the probes in the shortest time.

Double isolate design makes our testers safety with high strength and flame retardant materials.

Safe / smart / precise / highly efficient

Double isolated safe protection no burning, no electric shock, voltage and current intellgent setting,

High brightness disassemble no need.

Single LED light bar backlight check:

make sure the anode and acthode.

connect the probes to the anode and the cathode.

light up the single LED light bar backlight.

light up the double LED light bar backlight.

Package include:

1x Tester

2X gold plated pin

1x Power Cable

Attention:

The more quantity, the lower price. Please contact us for details.

CH003169
€14.92

0-300V On-Off switch Smart-Fit Voltage All Size LED LCD TV Laptop Backlight Tester Tool Lamp Beads Test

  • -20%

A1304 EMC 2253 Bios Chip EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9400 MB940LLA

PO000039
€18.00 €22.50

A1304 EMC 2253 Bios EFI Firmware 820-2375 Late 2008 Core 2 Duo SL9400 MB940LL/A

DY302 2500V 20G ohm Digital Insulation Resistance Tester Megger Megohmmeter

I.Specification:

* Three test voltage , the measured insulation resistance 20G

* 600V AC voltage measurement

* Low resistance buzzer

* Data hold , auto range

* Low battery warning

* Completion and testing lines , heavy suitcase and section six 1.5V AA batteries

Model DY30 - 1 DY30 - 2

The test voltage 250/500/1000V 500/1000/2500V

Resistance 0 ~ 2000M? (3% +5) 0 ~ 20G? (3% +5)

AC V 700V (2% +5) 700V (2% +5)

Auto range Yes

Function symbols are displayed Yes

Data Retention Yes

Low resistance buzzer Yes

Low battery warning Yes

LCD Max. Count 1999

Power AA1.5Vx6 (Not included)

Size 150 * 100 * 70 mm

NW About . 680 g

CH003175
€53.33

DY30-2 2500V 20G ohm Digital Insulation Resistance Tester Megger Megohmmeter

  • -20%

A1304 EMC 2334 Bios Chip EFI Firmware 820-2375 Mid2009 Core 2 Duo SL9400 MC233LLA

PO000040
€18.00 €22.50

A1304 EMC 2334 Bios EFI Firmware 820-2375 Mid-2009 Core 2 Duo SL9400 MC233LL/A

  • -20%

A1304 EMC 2334 Bios Chip EFI Firmware 820-2375 Mid2009 Core 2 Duo SL9600 MC234LLA

PO000041
€18.00 €22.50

A1304 EMC 2334 Bios EFI Firmware 820-2375 Mid-2009 Core 2 Duo SL9600 MC234LL/A

  • -20%

A1370 EMC 2393 Bios Chip EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9400 MC505LLA

PO000042
€18.00 €22.50

A1370 EMC 2393 Bios EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9400 MC505LL/A

  • -20%

A1370 EMC 2393 Bios Chip EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9600 MC906LLA

PO000043
€18.00 €22.50

A1370 EMC 2393 Bios EFI Firmware 820-2796 Late 2010 Core 2 Duo SU9600 MC906LL/A

Hantek DSO4202C Digital Oscilloscope 2CH 200MHz Bandwidth 1GSas

Features:

1.2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger;

2.The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously;

3.Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform;

4.Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions;

5.Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative;

6.Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle 7.wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.

8.Support SD card, VGA function (optional);

9.Integrated USB Host, Support USB disk storage, USB interface/SD card system update.

Specifications:

Model DSO4202C

Oscilloscope

Sample Rate Sampling Rate Range: 1GSa/s

Equivalent Sample Rate: 25GSa/s

Acquisition Modes

Normal Normal data only

Peak Detect High-frequency and randon glith capture

Average Wavefom Average, selectable 4,8,16,32,64,128

Inputs

Inputs Coupling AC, DC, GND

Inpits Impendance 1MO2% ?20pF3pF

Probe Attenuation 1X, 10X

Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X

Maximum Input Voltage CAT I and CAT II: 300VRMS (10)

CAT III: 150VRMS(1);

Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Horizontal

Sample Rate Range 1GS/s

Waveform Interpolation (sin x)/x

Record Length 40K

SEC/DIV Range 2ns/div to 40s/div 4ns/div to 40s/div

Sample Rate and 50ppm(at over any =1ms time interval)

Delay Time Accuracy

Position Range 2ns/div to 10ns/div; 20ns/div to 80us/div; (-8div x s/div) to 40ms;

(-4div x s/div) to 20ms; 200us/div to 40s/div; (-8div x s/div) to 400s

Delta Time Measurement Accuracy

(Full Bandwidth) Single-shot, Normal mode: (1 sample interval +100ppm reading + 0.6ns);

>16 averages: (1 sample interval + 100ppm reading + 0.4ns);

Sample interval = s/div 200

Vertical

Vertical Resolution 8-bit resolution, all channel sampled simultaneously

Position Range 2mV/div to 10V/div

Bandwidth 200MHz 100MHz 70MHz

Rise Time at BNC( typical) 1.8ns 3.5ns 5ns

Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, 400mV; 50mV/div to 200mV/div, 1V

500mV/div to 2V/div, 40V; 5V/div, 50V

Math +, -, *, /, FFT

FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;

1024 sample point

Bandwidth Limit 20MHz

Low Frequency Response (-3db) =10Hz at BNC

DC Gain Accuracy 3% for Normal or Average acquisition mode, 5V/div to 10mV/div;

4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy,

Average Acquisition Mode When vertical displacement is zero, and N =16: (3% reading + 0.1div + 1mV) only 10mV/div or greater is selected;

When vertical displacement is not zero, and N=16: [3% (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of =16 waveforms acquired under same setup and ambient conditions

Trigger System

Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source CH1, CH2, EXT, EXT/5, AC Line

Trigger Modes Auto, Normal, Single

Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject

Trigger Sensitivity

(Edge Trigger Type) DC(CH1,CH2):

1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;

DC(EXT):

200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;

DC(EXT/5):

1V from DC to 100MHz;1.75V from 100MHz to 200MHz;

AC: Attenuates signals below 10Hz;

HF Reject: Attenuates signals above 80kHz;

LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

Trigger Level Range CH1/CH2: 8 divisions from center of screen;

EXT: 1.2V;

EXT/5:6V

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times =20ns CH1/CH2: 0.2div volts/div within 4 divisions from center of screen;

EXT: (6% of setting + 40mV);

EXT/5: (6% of setting + 200mV);

Set Level to 50%(typical) Operates with input signals =50Hz

Video Trigger

Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;

EXT/5: 2V

Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range 100ns ~ 10s

Pulse Width Trigger

Pulse Width Trigger Mode Trigger when (< , >, = , or ?); Positive pulse or Negative pulse

Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.

Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

Less than: The trigger point is the trailing edge.

Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range 20ns ~ 10s

Slope Trigger

Slope Trigger Mode Trigger when (< , > , = , or ? ); Positive slope or Negative slope

Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.

Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than the set slope.

Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range 20ns ~ 10s

Overtime Trigger

Over Time Mode Rising edge or Falling edge

Time Range 20ns ~ 10s

Alternative Trigger

Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter

Readout Resolution 6 digits

Accuracy (typical) 30ppm (including all frequency reference errors and 1 count errors)

Frequency Range AC coupled, from 4Hz minimum to rated bandwidth

Signal Source Pulse Width or Edge Trigger modes: all available trigger sources

The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.

Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.

Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.

Video Trigger mode: The Frequency Counter does not work.

Measure

Cursor Measurement Voltage difference between cursors: ?V

Time difference between cursors: ?T

Reciprocal of ?T in Hertz (1/?T)

Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,

+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,

Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,

FRF, FFR, LRR, LRF, LFR, LFF

Signal Source Mode

Waveform Impedance DC-25MHz

Sample Rate 200MHzDDS

Output Waveform Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC

Frequency Resolution 0.1%

Waveform Depth 2KSa

Vertical Resolution 12bit

Frequency Stability <30ppm

Waveform Range -3.5V~+3.5V

Output Impedance 50O

Output Current 50mA Ipeak=100mA

System BW 25M

Harmonic Distortion -50dBc(1KHz),-40dBc(10KHz)

General Features

Display

Display Type 7 inch 64K color TFT (diagonal liquid crystal)

Display Resolution 800 horizontal by 480 vertical pixels

Display Contrast Adjustable (16 gears) with the progress bar

Probe Compensator Output

Output Voltage( typical) About 5Vpp into =1MO load

Frequency(typical) 1kHz

Power Supply

Supply Voltage 100-120VACRMS(10%), 45Hz to 440Hz, CAT?

120-240VACRMS(10%), 45Hz to 66Hz, CAT?

Power Consumption <30W

Fuse 2A, T rating, 250V

Environmental

Temperature Operating: 32? to 122? (0? to 50?);

Nonoperating: -40? to 159.8? (-40? to +71?)

Cooling Method Convection

Humidity +104? or below (+40? or below): =90% relative humidity;

106? to 122? (+41? to 50?): =60% relative humidity

Altitude Operating: Below 3,000m (10,000 feet);

Nonoperaring: Below 15,000m(50,000 feet)

Mechanical

Size Length 385mm, Width 200mm, Height 245mm

Weight 3.5KG(with Packing); 2.08KG(without Packing)

Package List:

1 x Digital Storage Oscilloscope

2 x Probes

1 x Oscilloscope Power line

1 x Hantek data CD

1 x USB line

1 x Manufacturer Certificate

CH003252
€364.26

Hantek DSO4202C Digital Oscilloscope 2CH 200MHz Bandwidth 1GSa/s