• Show Sidebar

There are 176 products.

Active filters

  • Categories: Ebay Store Chipsetpro
  • Categories: Multimeter, Test Tools
  • Categories: Programmer

TV160 Full HD LVDS Turn VGA LEDLCD TV Motherboard Tester Tools Converter Hot

TKDMR TV-160 Generation of LVDS Turn VGA Converter With The Display LCD/LED TV Motherboard Tester Mainboard Tool

Manual of Sixth-Generation LVDS-VGA Converter (Attached with device)

Thanks for choosing Sixth-Generation LVDS-VGA Converter (Display screen version)

developed by TD Please read this manual carefully before using. During LCTV

maintenance and production, the mainboard is required to be connected to a screen for testing;

however, due to miscellaneous mainboard specifications, various screens are required for

maintenance or production. In this case, this converted is developed to reduce the pressure of

manually installed screen and prevent the screen damage caused by the output signal of mainboard

fault which leads to tremendous loss. Taking this into consideration, this converter is able to

display LVDS from the mainboard directly or convert it into VGA for output. Besides, it is able to

be connected to a displayscreen for maintenance and commissioning.

To test the motherboard than 32 LVDS signals, comes with display. After the host first powered on, and then use the original machine screen line, then the corresponding adapter plate, in the case of a short circuit board did not give the board power adapter plate lights, and then inserted into the adapter plate converter on the host, this time will be able to host the display shows the image output board.

I. Characteristics of this conversion board

1. Furnished with 4.3" display screen, it is able to display LVDS image directly from the

mainboard, supporting external VGA.

2. It supports LVDS signal with various resolution ratios (60Hz, 120Hz and 240Hz) of single or

dual shielded wire.

3. It outputs uniform VGA signal (1280*720/60HZ) which is able to be connected to various

display, supporting CRT, liquid crystal and TV display (favorable compatibility).

4. The input interface features anti-static design with better anti-static capacity.

5. Convenient conversion among various LVDS formats.

6. Wide power input design, with 5V-12V adapter.

II. Packing list and standard accessories

Note standard accessories only include two normal shielded wire conversion boards, one

for two-interface with high definition and other for four-interface with standard definition. These

two conversion boards are compatible with most shielded wires on the market. Additional FFC,

special sanxing interface and another three mainboards are optional as shown below:

III. Select a conversion board (Please log in http://www.aliexpress.com/store/1937268 to inquire and purchase)

Note these three shielded wire conversion boards are not standard accessories, but they can be

purchased. The difference is that sanxing standard-definition conversion board with two

interfaces is thicker than the interface of configured standard-definition conversion board. The

other two FFC interfaces aim at conversion board with partial screen body being customized with

FFC interface. They have the same sequences with two standard conversion boards, but the

interface is FFC. The usage is shown at the back of manual.

IV. Functions about host of converter

Description of input mode conversion

Definition of LVDS input interface

Description of input mode conversion

This converter supports complete LVDS formats and supports conversion of various

resolution ratio input (6bit, 8bit, 10bit) into VGA signal (1280*720/60HZ), with favorable

compatibility with various displays. Conversion of LVDS signal formats is realized by pressing

the mode button circularly.

Parameter table of resolution and format of converter

No. Resolution LVDS format No. Resolution LVDS format

1 800*600 VASA, JEIDA 8 1280*720 VASA, JEIDA

2 1024*600 VASA, JEIDA 9 1600*900 VASA, JEIDA

3 1280*800 VASA, JEIDA 10 1400*1050 VASA, JEIDA

4 1280*1024 VASA, JEIDA 11 1680*1050 VASA, JEIDA

5 1366*768 VASA, JEIDA 12 1600*1200 VASA, JEIDA

6 1024*768 VASA, JEIDA 13 1920*1200 VASA, JEIDA

7 1440*900 VASA, JEIDA 14 1920*1080 VASA, JEIDA

1. It is prohibited to insert a shielded wire conversion board into a converter first. Instead, it

should be connected to a TV mainboard directly before switching on the TV mainboard. This

operation easily leads to shielded wire insertion fault and component damage. Please operate it

based on the following steps

2. Do not insert a shielded wire into a converter first. Instead, please insert the original shielded

wire of a TV mainboard into the converter. During insertion, LVDS signal wire sequence should

be aligned. After switching on the TV mainboard, the small board indicator light is on, indicating

that the termination of the shielded wire (wire sequence) is correct. Then insert the converter. It is

prohibited to insert the converter inside if the small indicator light is off; otherwise, the converter

might be damaged caused by the screen power supply entering LVDS input pin.

3. Generally, the single-route LVDS signal is able to be connected 0~3 (connection of group wire

4 is not necessary) in Group A and clock input by selecting LVDS wire. It is possible to connect 5

pairs of LVDS wire input. LVDS signal of Group A is able to support the resolution ratio up to

1366*768. LVDS with two- or four-route is able to be connected to this group only.

4. The LVDS input rule of this converter follows PCB wiring rule of LCD TV produced by

Skyworth, which conforms to standard of LVDS format in the industry of color TV.

5. This converter adopts wide power supply at 5V-12V (1A) and supports portable power source at

5V/1A, so its convenient to carry for test.

6. Attention: LVDS input end of this converter should not have the screen power connected to any

pin of the LVDS input end; otherwise, it might damage the main chip of the converter. The main

chip damage incurred by this falls beyond the guarantee scope.

V. Schematic diagram of converter connection

Manual of Shielded Wire Conversion Board of Sixth-Generation LVDS-VGA Converter

During mainboard maintenance or commissioning, the original TV shielded wire might not

match this LVDS-VGA converter input interface. This issue is able to be solved by the shielded

wire conversion board. The high definition interface of the shielded conversion board adopts

original imported interface, featuring long service life. The conversion board is sold as an

accessory of the LVDS-VGA converter. Refer to the following drawing description for the

shielded wire conversion board.

Diagram of usage of shielded wire conversion board

Step 1 Do not insert the conversion board into the converter. Instead, insert the original shielded

wire of TV mainboard into the corresponding shielded wire interface in the conversion board.

Note: the corresponding interface is based on the twisted-pair position of the shielded wire and the

position of small board LVDS paired wire, i.e. insert it correspondingly. Different shielded wire

should be inserted into different interfaces.

Step 2 Use one hand to press LVDS flat socket tightly and use the other to clench both ends of the

shielded wire to insert it in. The figure above is the high definition shielded wire interface. The

standard definition shielded wire interface follow the such insertion method. (Note: operation of

five small boards are basically identical. During connection, attention should be paid to the wire

sequence. Align the power supply before aligning the twisted-pair LVDS wire of a shielded wire and the paired signal wire of a small board.)

Step 3 Supply power to the TV mainboard. With a correct connection of a shielded wire, the indicator on

the small conversion board will be on; otherwise, it means connection of the shielded wire is

incorrect or the mainboard is not switched on. (Note: please inspect whether the mainboard screen

power supply (5 V/12 V) enters the right output pin; if it is, it will lead to a converter damage.

About an unfamiliar mainboard, a multi-meter should be used to inspect whether the contact pin

enters the screen power supply 5V/12V)

Step 4 It is able to be inserted (its front faces upwards) into the input base of LVDS ?VGA only if the

indicator on the shielded wire converter is on.

Step 5 After connection, if the mainboard of TV is normal, the display or external display on converter

will display the image of mainboard of TV.

If there is no image, check if the shielded wire is connected well or if any damage of mainboard.

In case of a blurred image, press the mode conversion button repeatedly to convert to various

modes till the image is normal.

To facilitate the mainboard testing on site, a portable power source is able to be used to supply

power to the converter. It is actually measured that Mi 10400 power (portable power from other

brand is able to be selected) is able to supply power to this converter for 15 hours, fully

conforming to testing requirements

Precautions of using converter

1. Please follow aforementioned operations strictly.

2. Firstly connect a mainboard with the shielded wire conversion board, with attention paid to the

wire sequence. Then switch on the TV mainboard, if the indicator on the shielded conversion

board is on, it means connection between the mainboard and the shielded wire board is correct;

otherwise, it should be re-inspected

3. With correct connection between the shielded wire conversion board and the mainboard, insert

the shielded wire conversion board (front faces upwards) into the LVDS converter (refer to the

figure above) before putting the TV mainboard and the converter to switching on status.

4. In case of a blurred image, press the mode conversion button repeatedly to convert to various

modes till the image is normal.

5. This converter supports various LVDS formats (60Hz, 120Hz and 240Hz). About a mainboard

with two shielded wire, one wire alone is required to be connected to the high definition

conversion board instead of both wires. Besides, it is able to convert required image.

6. Please follow aforementioned operations strictly!

Accessories

Standard accessories include two conversion boards, one for two-interface with high definition

and other for four-interface with standard definition. These two conversion boards are compatible

with interface of 32and 58 display screen.

CH004123
€172.00

TV160 Full HD LVDS Turn VGA (LED/LCD) TV Motherboard Tester Tools Converter Hot

GS320 NonContact Laser LCD Display Digital IR Infrared Thermometer Temperature

Features:

Measuring range : -50~360? (-58~680?)

Accuracy : 1.5? / 1.5%

Resolution : 0.1? or 0.1?

Distance spot ratio : 12 : 1

Emissivity : 0.95 (fixed)

?/? unit selectable

Auto power off & Data Hold

Laser ON/OFF selectable

backlight ON/OFF selectable

Red Laser Power : less than 0.5 MW

Power supply : 2 x 1.5V AAA battery (Not included.)

Product Dimension : 140 x 85 x 35mm (L x W x H)

Package includes :

1x GS320 Infrared Thermometer

1 x User Manual

CH004191
€16.04

GS320 Non-Contact Laser LCD Display Digital IR Infrared Thermometer Temperature

Hantek 6212BE Digital Storage Oscilloscope Virtual Oscillosco2CH 200MHz 250MSas

Hantek 6212BE Automotive Oscilloscope 2Channels 200MHz 250MSa/s USB PC Based Digital Storage Oscilloscope Virtual Oscilloscope Logic Analyzer Diagnostic Tool

Hantek 6212BE 2CH USB PC Digital Storage Oscilloscope Virtual Oscilloscope 200MHz 250MS/s Diagnostic Tool

Login to Download: * User Manual Buy Probe Accessories

Features:

Excellent industrial design-the same anodisedaluminium casing as iPad,

which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.

Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.

USB2.0 interface, no external power source required, easy to use.

Be suitable for notebook computer, product line maintenance,be used easily on business.

Dimensions (mm):190(L) x100(W) x35(H), be carried easily.

High performance, 250MS/s real-time sampling, 200MHz Bandwidth.

Operating System: Windows 7, Windows NT, Windows 2000, Windows XP,VISTA.

23 measurement functions, PASS/FAIL Check, be suitable for technical application.

Waveform average, persistence, intensity,invert,addition, subtraction, multiplication, division,X-Y plot.

Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.

FFT

One computer can connect many DSO, extend channel easily.

LabviewVBVCDelphiC++Builder Second Design instance.

16CH + 2CH oscilloscope logic analyzer

48MS / s sampling rate, 1M / CH memory depth

USBXITM standard interface to facilitate insertion USBXITM chassis, consisting of a combination of instruments

USB2.0 interface, no external power source, similar to a desktop oscilloscope interface, easy to use

More suitable for notebooks, production line maintenance, be used easily on business

Small size (mm): 200 (L) x100 (W) x35 (H), easy to carry

High refresh rate, high sampling rate, 48MSa / s real-time sampling

Software Support: Windows 7, Windows NT, Windows XP, VISTA

More than 20 kinds of automatic measurement functions

Intensity, invert, addition, subtraction, multiplication, division, X-Y display

Waveform data can be time and voltage output to EXCEL, BMP, JPG

FFT spectrum analysis

A computer can connect many DSO, extend channel easily

Provide secondary development VB, VC, Labview

Parameters:

Max. sample rate

Real-time sampling:

250MSa/s using one channel(Hantek6102BE)

250MSa/s using one channel(Hantek6212BE)

Channels

2

Bandwidth

100 MHz analog bandwidth(Hantek6102BE)

200 MHz analog bandwidth(Hantek6212BE)

Vertical Resolution

8 bits/channel (Hantek6102BE)

9 bits/channel (Hantek6212BE)

Gain range

Hantek6102BE

10mV ~5V/div @ x1 probe(1,2,5 sequence)

100mV ~ 50V/div @ x10 probe

1V ~ 500V/div @ x100 probe

10V ~ 5KV/div @ x1000 probe

Hantek6212BE

10mV ~10V/div @ x1 probe(1,2,5 sequence)

100mV ~100V/div @ x10 probe

1V ~ 1000V/div @ x100 probe

10V ~ 10KV/div @ x1000 probe

Range

8 divisions

Offset level

+/-4 divisions

Coupling

AC, DC,GND

Offset increments

0.02 div

Impedance

1M ohm

DC accuracy

+/-3%

Input protection

35Vpk (DC + peak AC < 10 kHz, without external attenuation)

Display Mode

Y-T, X-Y and Roll

Timebase

Timebase range

Hantek6102BE

4ns/div-1h/div(1-2-4 sequence)

Hantek6212BE

2ns/div-1h/div(1-2-4 sequence)

Acquisition mode

Hantek6102BE

Real-time sampling: 4ns/div-400ms/div.

Roll mode: 1s/div-1h/div

Hantek6212BE

Equivalent sampling: 2ns/div ~ 4us/div

Real-time sampling: 10us/div ~ 400ms/div

Roll mode: 1s/div ~ 1h/div

Range

10 divisions

Buffer Size

10K ~ 1M

Trigger

Type

Hantek6102BE

Edge trigger

Hantek6212BE

Edge trigger, Pulse Trigger

Mode

Auto, Normal and Single

Package Content:

1*Hantek 6212BE Host

1*User Manual

CH004214
€340.64

Hantek 6212BE Digital Storage Oscilloscope Virtual Oscillosco2CH 200MHz 250MSa/s

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

Use Tutorials Video: * Check

The disadvantage of this test indicates that some models cannot be tested when the resolution of this tester is above 3K. Ltn133yl02 / 03 / 04 / 05 / 06 can not be tested normally, so only self-test line can be used. Other LCDs with resolution above 3K do not promise to test normally. The resolution below 3K is no problem.

1. This EDP tester has intelligent screen parameter configuration function, 6-bit screen uses 01, 8-bit screen uses 02. In general, the screen with 1920 * 1080 resolution and above uses 02, and the screen with 1920 * 1080 resolution and below uses 01. When you don't know the resolution, you can try 02 first. In all EDP screens, about 10% of the screens can not match the intelligent screen parameters, so it is necessary to use the accurate screen parameter number.

2. For the configuration of accurate screen reference number, first search the LCD screen model to be tested in Baidu to determine the screen type and resolution. Then query the corresponding number. Each resolution is divided into 6-digit and 8-digit, with a total of 6 numbers. It is generally recommended to use 8-digit screen reference number first.

3 EDP screen is usually 30 pins with 0.5 spacing. The standard line of the screen tester can measure 80% EDP screen with 1920 * 1080 resolution and below, which is different from LVDS screen. The screen with 2K resolution or above and the screen line with standard configuration can not be tested normally needs to be made by hand, and the LCD screen needs to be provided at the same time. Generally, it is connected to ports a, C and D of the tester. When the screen is bright, but the screen is flashing or black, port B, C and D are used. If some manual lines do not have port C, only port B and D are needed. The standard line of EDP screen whose screen model starts with vvx can't be applied, so it must be done manually again. Au screen containing b116htn, b133htn, b140htn and b156htn can be normally displayed with B, C and D. Qimei's n133hse-ea3 / EB3 can be displayed normally only with B, C and D.

4. If a, C, D or B, C, D glass signal image display is normal but the backlight is not bright, it means that the screen does not have its own backlight boost module, and it needs to do the screen connecting line and external constant current board manually.

CH004231
€317.02

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

ZOTEK ZT203 6000 Counts Pentype Digital Multimeter True RMS Auto Range DCAC Voltage Meter Voltmeter with Backlight

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

Description:

This is battery-powered, true RMS, auto-ranging, pen-type digital multimeter with 6000

counts backlight LCD display.

Five functional buttons instead of the traditional rotary switch enable one-hand operation.

This product is made of high quality material and durable, which can prevent breakage.

Features:

5 functional buttons: instead of the traditional rotary switch, 5 buttons can make you

measurements more convenient and efficient.

True RMS: The RMS/DC transform avoids the influence of voltage waveform distortion can test high accuracy.

LCD Display: 6000 counts digital LCD display offers large test rang as well as clear readings.

7 Test Modes: used to test DC & AC voltage, capacitance, resistance, frequency, continuity,

diode and NCV.

Humanized Design: it comes with auto power off, data hold, auto/manual range.

Specifications:

Material: Plastic

Display: LCD display with backlight

DC Voltage Range: 60mV/600mV/6V/60V/600V/1000V

AC Voltage Range: 60mV/600mV/6V/60V/600V/750V

Resistance Range: 600O/6kO/60kO/600kO/6MO/60MO

Capacitance Range: 9.999nF/99.99nF/999.9nF/9.999F/99.99F/999.9F/9.999mF

Frequency: 99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz

Diode: yes

Continuity: yes

NVC: yes

Maximum display: 6000

Automatic range/manual range: yes

True effective value: yes

Data retention: yes

Flashlight: yes

Low battery tip: yes

Automatic shutdown: yes

Relative value measurement: yes

Supply power: 2 x 1.5V AAA batteries (not included)

Item dimension:

Item Size: 20.2cm x 5.1cm x 3.4cm/7.6 x 2 x 1.3in

Item Weight: 114g/4oz

Package information:

Package Size: 23.2* 9 * 5.5cm / 9.1 * 3.5 * 2.7in

Package Weight: 267g/9.4oz

Gift box package

Package List:

1 x Digital Multimeter

1 x Pair of Test Leads

1 x Black soft case

1 x User Manual(English)

CH004292
€22.75

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

More Similar Products

1 Pair 1000V 20A Universal Digital Multimeter Meter Probe Test Leads 3mm Pin Red + Black

Features :

100% brand new and high quality.

The anterior gold-plated design, in the test, the sensitivity of pens and higher and more accurate.

22mm Plug Insertion Depth.

Up to 20A / 1000V

Material: PVC and Alloy

Color: Black + Red

Package includeds :

1 x Pair of Digital Multimeter Meter Probe

CH004435
€2.70

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

TV160 Full HD LVDS Turn VGA LEDLCD TV Motherboard Tester Tools Converter Hot

TKDMR TV-160 Generation of LVDS Turn VGA Converter With The Display LCD/LED TV Motherboard Tester Mainboard Tool

Manual of Sixth-Generation LVDS-VGA Converter (Attached with device)

Thanks for choosing Sixth-Generation LVDS-VGA Converter (Display screen version)

developed by TD Please read this manual carefully before using. During LCTV

maintenance and production, the mainboard is required to be connected to a screen for testing;

however, due to miscellaneous mainboard specifications, various screens are required for

maintenance or production. In this case, this converted is developed to reduce the pressure of

manually installed screen and prevent the screen damage caused by the output signal of mainboard

fault which leads to tremendous loss. Taking this into consideration, this converter is able to

display LVDS from the mainboard directly or convert it into VGA for output. Besides, it is able to

be connected to a displayscreen for maintenance and commissioning.

To test the motherboard than 32 LVDS signals, comes with display. After the host first powered on, and then use the original machine screen line, then the corresponding adapter plate, in the case of a short circuit board did not give the board power adapter plate lights, and then inserted into the adapter plate converter on the host, this time will be able to host the display shows the image output board.

I. Characteristics of this conversion board

1. Furnished with 4.3" display screen, it is able to display LVDS image directly from the

mainboard, supporting external VGA.

2. It supports LVDS signal with various resolution ratios (60Hz, 120Hz and 240Hz) of single or

dual shielded wire.

3. It outputs uniform VGA signal (1280*720/60HZ) which is able to be connected to various

display, supporting CRT, liquid crystal and TV display (favorable compatibility).

4. The input interface features anti-static design with better anti-static capacity.

5. Convenient conversion among various LVDS formats.

6. Wide power input design, with 5V-12V adapter.

II. Packing list and standard accessories

Note standard accessories only include two normal shielded wire conversion boards, one

for two-interface with high definition and other for four-interface with standard definition. These

two conversion boards are compatible with most shielded wires on the market. Additional FFC,

special sanxing interface and another three mainboards are optional as shown below:

III. Select a conversion board (Please log in http://www.aliexpress.com/store/1937268 to inquire and purchase)

Note these three shielded wire conversion boards are not standard accessories, but they can be

purchased. The difference is that sanxing standard-definition conversion board with two

interfaces is thicker than the interface of configured standard-definition conversion board. The

other two FFC interfaces aim at conversion board with partial screen body being customized with

FFC interface. They have the same sequences with two standard conversion boards, but the

interface is FFC. The usage is shown at the back of manual.

IV. Functions about host of converter

Description of input mode conversion

Definition of LVDS input interface

Description of input mode conversion

This converter supports complete LVDS formats and supports conversion of various

resolution ratio input (6bit, 8bit, 10bit) into VGA signal (1280*720/60HZ), with favorable

compatibility with various displays. Conversion of LVDS signal formats is realized by pressing

the mode button circularly.

Parameter table of resolution and format of converter

No. Resolution LVDS format No. Resolution LVDS format

1 800*600 VASA, JEIDA 8 1280*720 VASA, JEIDA

2 1024*600 VASA, JEIDA 9 1600*900 VASA, JEIDA

3 1280*800 VASA, JEIDA 10 1400*1050 VASA, JEIDA

4 1280*1024 VASA, JEIDA 11 1680*1050 VASA, JEIDA

5 1366*768 VASA, JEIDA 12 1600*1200 VASA, JEIDA

6 1024*768 VASA, JEIDA 13 1920*1200 VASA, JEIDA

7 1440*900 VASA, JEIDA 14 1920*1080 VASA, JEIDA

1. It is prohibited to insert a shielded wire conversion board into a converter first. Instead, it

should be connected to a TV mainboard directly before switching on the TV mainboard. This

operation easily leads to shielded wire insertion fault and component damage. Please operate it

based on the following steps

2. Do not insert a shielded wire into a converter first. Instead, please insert the original shielded

wire of a TV mainboard into the converter. During insertion, LVDS signal wire sequence should

be aligned. After switching on the TV mainboard, the small board indicator light is on, indicating

that the termination of the shielded wire (wire sequence) is correct. Then insert the converter. It is

prohibited to insert the converter inside if the small indicator light is off; otherwise, the converter

might be damaged caused by the screen power supply entering LVDS input pin.

3. Generally, the single-route LVDS signal is able to be connected 0~3 (connection of group wire

4 is not necessary) in Group A and clock input by selecting LVDS wire. It is possible to connect 5

pairs of LVDS wire input. LVDS signal of Group A is able to support the resolution ratio up to

1366*768. LVDS with two- or four-route is able to be connected to this group only.

4. The LVDS input rule of this converter follows PCB wiring rule of LCD TV produced by

Skyworth, which conforms to standard of LVDS format in the industry of color TV.

5. This converter adopts wide power supply at 5V-12V (1A) and supports portable power source at

5V/1A, so its convenient to carry for test.

6. Attention: LVDS input end of this converter should not have the screen power connected to any

pin of the LVDS input end; otherwise, it might damage the main chip of the converter. The main

chip damage incurred by this falls beyond the guarantee scope.

V. Schematic diagram of converter connection

Manual of Shielded Wire Conversion Board of Sixth-Generation LVDS-VGA Converter

During mainboard maintenance or commissioning, the original TV shielded wire might not

match this LVDS-VGA converter input interface. This issue is able to be solved by the shielded

wire conversion board. The high definition interface of the shielded conversion board adopts

original imported interface, featuring long service life. The conversion board is sold as an

accessory of the LVDS-VGA converter. Refer to the following drawing description for the

shielded wire conversion board.

Diagram of usage of shielded wire conversion board

Step 1 Do not insert the conversion board into the converter. Instead, insert the original shielded

wire of TV mainboard into the corresponding shielded wire interface in the conversion board.

Note: the corresponding interface is based on the twisted-pair position of the shielded wire and the

position of small board LVDS paired wire, i.e. insert it correspondingly. Different shielded wire

should be inserted into different interfaces.

Step 2 Use one hand to press LVDS flat socket tightly and use the other to clench both ends of the

shielded wire to insert it in. The figure above is the high definition shielded wire interface. The

standard definition shielded wire interface follow the such insertion method. (Note: operation of

five small boards are basically identical. During connection, attention should be paid to the wire

sequence. Align the power supply before aligning the twisted-pair LVDS wire of a shielded wire and the paired signal wire of a small board.)

Step 3 Supply power to the TV mainboard. With a correct connection of a shielded wire, the indicator on

the small conversion board will be on; otherwise, it means connection of the shielded wire is

incorrect or the mainboard is not switched on. (Note: please inspect whether the mainboard screen

power supply (5 V/12 V) enters the right output pin; if it is, it will lead to a converter damage.

About an unfamiliar mainboard, a multi-meter should be used to inspect whether the contact pin

enters the screen power supply 5V/12V)

Step 4 It is able to be inserted (its front faces upwards) into the input base of LVDS ?VGA only if the

indicator on the shielded wire converter is on.

Step 5 After connection, if the mainboard of TV is normal, the display or external display on converter

will display the image of mainboard of TV.

If there is no image, check if the shielded wire is connected well or if any damage of mainboard.

In case of a blurred image, press the mode conversion button repeatedly to convert to various

modes till the image is normal.

To facilitate the mainboard testing on site, a portable power source is able to be used to supply

power to the converter. It is actually measured that Mi 10400 power (portable power from other

brand is able to be selected) is able to supply power to this converter for 15 hours, fully

conforming to testing requirements

Precautions of using converter

1. Please follow aforementioned operations strictly.

2. Firstly connect a mainboard with the shielded wire conversion board, with attention paid to the

wire sequence. Then switch on the TV mainboard, if the indicator on the shielded conversion

board is on, it means connection between the mainboard and the shielded wire board is correct;

otherwise, it should be re-inspected

3. With correct connection between the shielded wire conversion board and the mainboard, insert

the shielded wire conversion board (front faces upwards) into the LVDS converter (refer to the

figure above) before putting the TV mainboard and the converter to switching on status.

4. In case of a blurred image, press the mode conversion button repeatedly to convert to various

modes till the image is normal.

5. This converter supports various LVDS formats (60Hz, 120Hz and 240Hz). About a mainboard

with two shielded wire, one wire alone is required to be connected to the high definition

conversion board instead of both wires. Besides, it is able to convert required image.

6. Please follow aforementioned operations strictly!

Accessories

Standard accessories include two conversion boards, one for two-interface with high definition

and other for four-interface with standard definition. These two conversion boards are compatible

with interface of 32and 58 display screen.

CH004123
€172.00

TV160 Full HD LVDS Turn VGA (LED/LCD) TV Motherboard Tester Tools Converter Hot

GS320 NonContact Laser LCD Display Digital IR Infrared Thermometer Temperature

Features:

Measuring range : -50~360? (-58~680?)

Accuracy : 1.5? / 1.5%

Resolution : 0.1? or 0.1?

Distance spot ratio : 12 : 1

Emissivity : 0.95 (fixed)

?/? unit selectable

Auto power off & Data Hold

Laser ON/OFF selectable

backlight ON/OFF selectable

Red Laser Power : less than 0.5 MW

Power supply : 2 x 1.5V AAA battery (Not included.)

Product Dimension : 140 x 85 x 35mm (L x W x H)

Package includes :

1x GS320 Infrared Thermometer

1 x User Manual

CH004191
€16.04

GS320 Non-Contact Laser LCD Display Digital IR Infrared Thermometer Temperature

Hantek 6212BE Digital Storage Oscilloscope Virtual Oscillosco2CH 200MHz 250MSas

Hantek 6212BE Automotive Oscilloscope 2Channels 200MHz 250MSa/s USB PC Based Digital Storage Oscilloscope Virtual Oscilloscope Logic Analyzer Diagnostic Tool

Hantek 6212BE 2CH USB PC Digital Storage Oscilloscope Virtual Oscilloscope 200MHz 250MS/s Diagnostic Tool

Login to Download: * User Manual Buy Probe Accessories

Features:

Excellent industrial design-the same anodisedaluminium casing as iPad,

which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.

Standard USBXI TM interface, easily inserts into USBXI TM housing to make up a combination instrument.

USB2.0 interface, no external power source required, easy to use.

Be suitable for notebook computer, product line maintenance,be used easily on business.

Dimensions (mm):190(L) x100(W) x35(H), be carried easily.

High performance, 250MS/s real-time sampling, 200MHz Bandwidth.

Operating System: Windows 7, Windows NT, Windows 2000, Windows XP,VISTA.

23 measurement functions, PASS/FAIL Check, be suitable for technical application.

Waveform average, persistence, intensity,invert,addition, subtraction, multiplication, division,X-Y plot.

Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.

FFT

One computer can connect many DSO, extend channel easily.

LabviewVBVCDelphiC++Builder Second Design instance.

16CH + 2CH oscilloscope logic analyzer

48MS / s sampling rate, 1M / CH memory depth

USBXITM standard interface to facilitate insertion USBXITM chassis, consisting of a combination of instruments

USB2.0 interface, no external power source, similar to a desktop oscilloscope interface, easy to use

More suitable for notebooks, production line maintenance, be used easily on business

Small size (mm): 200 (L) x100 (W) x35 (H), easy to carry

High refresh rate, high sampling rate, 48MSa / s real-time sampling

Software Support: Windows 7, Windows NT, Windows XP, VISTA

More than 20 kinds of automatic measurement functions

Intensity, invert, addition, subtraction, multiplication, division, X-Y display

Waveform data can be time and voltage output to EXCEL, BMP, JPG

FFT spectrum analysis

A computer can connect many DSO, extend channel easily

Provide secondary development VB, VC, Labview

Parameters:

Max. sample rate

Real-time sampling:

250MSa/s using one channel(Hantek6102BE)

250MSa/s using one channel(Hantek6212BE)

Channels

2

Bandwidth

100 MHz analog bandwidth(Hantek6102BE)

200 MHz analog bandwidth(Hantek6212BE)

Vertical Resolution

8 bits/channel (Hantek6102BE)

9 bits/channel (Hantek6212BE)

Gain range

Hantek6102BE

10mV ~5V/div @ x1 probe(1,2,5 sequence)

100mV ~ 50V/div @ x10 probe

1V ~ 500V/div @ x100 probe

10V ~ 5KV/div @ x1000 probe

Hantek6212BE

10mV ~10V/div @ x1 probe(1,2,5 sequence)

100mV ~100V/div @ x10 probe

1V ~ 1000V/div @ x100 probe

10V ~ 10KV/div @ x1000 probe

Range

8 divisions

Offset level

+/-4 divisions

Coupling

AC, DC,GND

Offset increments

0.02 div

Impedance

1M ohm

DC accuracy

+/-3%

Input protection

35Vpk (DC + peak AC < 10 kHz, without external attenuation)

Display Mode

Y-T, X-Y and Roll

Timebase

Timebase range

Hantek6102BE

4ns/div-1h/div(1-2-4 sequence)

Hantek6212BE

2ns/div-1h/div(1-2-4 sequence)

Acquisition mode

Hantek6102BE

Real-time sampling: 4ns/div-400ms/div.

Roll mode: 1s/div-1h/div

Hantek6212BE

Equivalent sampling: 2ns/div ~ 4us/div

Real-time sampling: 10us/div ~ 400ms/div

Roll mode: 1s/div ~ 1h/div

Range

10 divisions

Buffer Size

10K ~ 1M

Trigger

Type

Hantek6102BE

Edge trigger

Hantek6212BE

Edge trigger, Pulse Trigger

Mode

Auto, Normal and Single

Package Content:

1*Hantek 6212BE Host

1*User Manual

CH004214
€340.64

Hantek 6212BE Digital Storage Oscilloscope Virtual Oscillosco2CH 200MHz 250MSa/s

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

Use Tutorials Video: * Check

The disadvantage of this test indicates that some models cannot be tested when the resolution of this tester is above 3K. Ltn133yl02 / 03 / 04 / 05 / 06 can not be tested normally, so only self-test line can be used. Other LCDs with resolution above 3K do not promise to test normally. The resolution below 3K is no problem.

1. This EDP tester has intelligent screen parameter configuration function, 6-bit screen uses 01, 8-bit screen uses 02. In general, the screen with 1920 * 1080 resolution and above uses 02, and the screen with 1920 * 1080 resolution and below uses 01. When you don't know the resolution, you can try 02 first. In all EDP screens, about 10% of the screens can not match the intelligent screen parameters, so it is necessary to use the accurate screen parameter number.

2. For the configuration of accurate screen reference number, first search the LCD screen model to be tested in Baidu to determine the screen type and resolution. Then query the corresponding number. Each resolution is divided into 6-digit and 8-digit, with a total of 6 numbers. It is generally recommended to use 8-digit screen reference number first.

3 EDP screen is usually 30 pins with 0.5 spacing. The standard line of the screen tester can measure 80% EDP screen with 1920 * 1080 resolution and below, which is different from LVDS screen. The screen with 2K resolution or above and the screen line with standard configuration can not be tested normally needs to be made by hand, and the LCD screen needs to be provided at the same time. Generally, it is connected to ports a, C and D of the tester. When the screen is bright, but the screen is flashing or black, port B, C and D are used. If some manual lines do not have port C, only port B and D are needed. The standard line of EDP screen whose screen model starts with vvx can't be applied, so it must be done manually again. Au screen containing b116htn, b133htn, b140htn and b156htn can be normally displayed with B, C and D. Qimei's n133hse-ea3 / EB3 can be displayed normally only with B, C and D.

4. If a, C, D or B, C, D glass signal image display is normal but the backlight is not bright, it means that the screen does not have its own backlight boost module, and it needs to do the screen connecting line and external constant current board manually.

CH004231
€317.02

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

ZOTEK ZT203 6000 Counts Pentype Digital Multimeter True RMS Auto Range DCAC Voltage Meter Voltmeter with Backlight

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

Description:

This is battery-powered, true RMS, auto-ranging, pen-type digital multimeter with 6000

counts backlight LCD display.

Five functional buttons instead of the traditional rotary switch enable one-hand operation.

This product is made of high quality material and durable, which can prevent breakage.

Features:

5 functional buttons: instead of the traditional rotary switch, 5 buttons can make you

measurements more convenient and efficient.

True RMS: The RMS/DC transform avoids the influence of voltage waveform distortion can test high accuracy.

LCD Display: 6000 counts digital LCD display offers large test rang as well as clear readings.

7 Test Modes: used to test DC & AC voltage, capacitance, resistance, frequency, continuity,

diode and NCV.

Humanized Design: it comes with auto power off, data hold, auto/manual range.

Specifications:

Material: Plastic

Display: LCD display with backlight

DC Voltage Range: 60mV/600mV/6V/60V/600V/1000V

AC Voltage Range: 60mV/600mV/6V/60V/600V/750V

Resistance Range: 600O/6kO/60kO/600kO/6MO/60MO

Capacitance Range: 9.999nF/99.99nF/999.9nF/9.999F/99.99F/999.9F/9.999mF

Frequency: 99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz

Diode: yes

Continuity: yes

NVC: yes

Maximum display: 6000

Automatic range/manual range: yes

True effective value: yes

Data retention: yes

Flashlight: yes

Low battery tip: yes

Automatic shutdown: yes

Relative value measurement: yes

Supply power: 2 x 1.5V AAA batteries (not included)

Item dimension:

Item Size: 20.2cm x 5.1cm x 3.4cm/7.6 x 2 x 1.3in

Item Weight: 114g/4oz

Package information:

Package Size: 23.2* 9 * 5.5cm / 9.1 * 3.5 * 2.7in

Package Weight: 267g/9.4oz

Gift box package

Package List:

1 x Digital Multimeter

1 x Pair of Test Leads

1 x Black soft case

1 x User Manual(English)

CH004292
€22.75

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

More Similar Products

1 Pair 1000V 20A Universal Digital Multimeter Meter Probe Test Leads 3mm Pin Red + Black

Features :

100% brand new and high quality.

The anterior gold-plated design, in the test, the sensitivity of pens and higher and more accurate.

22mm Plug Insertion Depth.

Up to 20A / 1000V

Material: PVC and Alloy

Color: Black + Red

Package includeds :

1 x Pair of Digital Multimeter Meter Probe

CH004435
€2.70

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y