• Show Sidebar

There are 697 products.

Active filters

  • Categories: CPU and Graphic Chips
  • Categories: Multimeter, Test Tools
  • Condition: New

MCP67MVA2

MCP67MV-A2

Part Number MCP67MV-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 10+

Package/Case 240 PCS Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001247
€73.85

MCP67MV-A2

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

Use Tutorials Video: * Check

The disadvantage of this test indicates that some models cannot be tested when the resolution of this tester is above 3K. Ltn133yl02 / 03 / 04 / 05 / 06 can not be tested normally, so only self-test line can be used. Other LCDs with resolution above 3K do not promise to test normally. The resolution below 3K is no problem.

1. This EDP tester has intelligent screen parameter configuration function, 6-bit screen uses 01, 8-bit screen uses 02. In general, the screen with 1920 * 1080 resolution and above uses 02, and the screen with 1920 * 1080 resolution and below uses 01. When you don't know the resolution, you can try 02 first. In all EDP screens, about 10% of the screens can not match the intelligent screen parameters, so it is necessary to use the accurate screen parameter number.

2. For the configuration of accurate screen reference number, first search the LCD screen model to be tested in Baidu to determine the screen type and resolution. Then query the corresponding number. Each resolution is divided into 6-digit and 8-digit, with a total of 6 numbers. It is generally recommended to use 8-digit screen reference number first.

3 EDP screen is usually 30 pins with 0.5 spacing. The standard line of the screen tester can measure 80% EDP screen with 1920 * 1080 resolution and below, which is different from LVDS screen. The screen with 2K resolution or above and the screen line with standard configuration can not be tested normally needs to be made by hand, and the LCD screen needs to be provided at the same time. Generally, it is connected to ports a, C and D of the tester. When the screen is bright, but the screen is flashing or black, port B, C and D are used. If some manual lines do not have port C, only port B and D are needed. The standard line of EDP screen whose screen model starts with vvx can't be applied, so it must be done manually again. Au screen containing b116htn, b133htn, b140htn and b156htn can be normally displayed with B, C and D. Qimei's n133hse-ea3 / EB3 can be displayed normally only with B, C and D.

4. If a, C, D or B, C, D glass signal image display is normal but the backlight is not bright, it means that the screen does not have its own backlight boost module, and it needs to do the screen connecting line and external constant current board manually.

CH004231
€317.02

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

ZOTEK ZT203 6000 Counts Pentype Digital Multimeter True RMS Auto Range DCAC Voltage Meter Voltmeter with Backlight

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

Description:

This is battery-powered, true RMS, auto-ranging, pen-type digital multimeter with 6000

counts backlight LCD display.

Five functional buttons instead of the traditional rotary switch enable one-hand operation.

This product is made of high quality material and durable, which can prevent breakage.

Features:

5 functional buttons: instead of the traditional rotary switch, 5 buttons can make you

measurements more convenient and efficient.

True RMS: The RMS/DC transform avoids the influence of voltage waveform distortion can test high accuracy.

LCD Display: 6000 counts digital LCD display offers large test rang as well as clear readings.

7 Test Modes: used to test DC & AC voltage, capacitance, resistance, frequency, continuity,

diode and NCV.

Humanized Design: it comes with auto power off, data hold, auto/manual range.

Specifications:

Material: Plastic

Display: LCD display with backlight

DC Voltage Range: 60mV/600mV/6V/60V/600V/1000V

AC Voltage Range: 60mV/600mV/6V/60V/600V/750V

Resistance Range: 600O/6kO/60kO/600kO/6MO/60MO

Capacitance Range: 9.999nF/99.99nF/999.9nF/9.999F/99.99F/999.9F/9.999mF

Frequency: 99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz

Diode: yes

Continuity: yes

NVC: yes

Maximum display: 6000

Automatic range/manual range: yes

True effective value: yes

Data retention: yes

Flashlight: yes

Low battery tip: yes

Automatic shutdown: yes

Relative value measurement: yes

Supply power: 2 x 1.5V AAA batteries (not included)

Item dimension:

Item Size: 20.2cm x 5.1cm x 3.4cm/7.6 x 2 x 1.3in

Item Weight: 114g/4oz

Package information:

Package Size: 23.2* 9 * 5.5cm / 9.1 * 3.5 * 2.7in

Package Weight: 267g/9.4oz

Gift box package

Package List:

1 x Digital Multimeter

1 x Pair of Test Leads

1 x Black soft case

1 x User Manual(English)

CH004292
€22.75

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

2160842009 HD8730M

216-0842009 HD8730M

Part Number 216-0842009 Manufacturer AMD

BGA Alloy No Pb/Lead Free Date Code 1234

Package/Case 360 Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001251
€67.04

216-0842009 HD8730M

N15VGMSA2

N15V-GM-S-A2

Part Number N15V-GM-S-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 13+

Package/Case 1 PCS Description Brand new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001262
€24.62

N15V-GM-S-A2

FH82HM370 SR40B

FH82HM370 SR40B

Part Number SR408 Manufacturer INTEL

BGA Alloy No Pb/Lead Free Date Code 16+

Package/Case 1 PCS Description Brand new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001266
€62.36

FH82HM370 SR40B

QDFX350MTNA3

QD-FX-350MT-N-A3

Part Number QD-FX-350MT-N-A3 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 0952

Package/Case 600 PCS Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001277
€21.33

QD-FX-350MT-N-A3

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

More Similar Products

1 Pair 1000V 20A Universal Digital Multimeter Meter Probe Test Leads 3mm Pin Red + Black

Features :

100% brand new and high quality.

The anterior gold-plated design, in the test, the sensitivity of pens and higher and more accurate.

22mm Plug Insertion Depth.

Up to 20A / 1000V

Material: PVC and Alloy

Color: Black + Red

Package includeds :

1 x Pair of Digital Multimeter Meter Probe

CH004435
€2.70

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

G73VZANA2

G73-VZA-N-A2

Part Number G73-VZA-N-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 1018

Package/Case 240 Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001286
€24.62

G73-VZA-N-A2

MCP67MVA2

MCP67MV-A2

Part Number MCP67MV-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 10+

Package/Case 240 PCS Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001247
€73.85

MCP67MV-A2

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

Use Tutorials Video: * Check

The disadvantage of this test indicates that some models cannot be tested when the resolution of this tester is above 3K. Ltn133yl02 / 03 / 04 / 05 / 06 can not be tested normally, so only self-test line can be used. Other LCDs with resolution above 3K do not promise to test normally. The resolution below 3K is no problem.

1. This EDP tester has intelligent screen parameter configuration function, 6-bit screen uses 01, 8-bit screen uses 02. In general, the screen with 1920 * 1080 resolution and above uses 02, and the screen with 1920 * 1080 resolution and below uses 01. When you don't know the resolution, you can try 02 first. In all EDP screens, about 10% of the screens can not match the intelligent screen parameters, so it is necessary to use the accurate screen parameter number.

2. For the configuration of accurate screen reference number, first search the LCD screen model to be tested in Baidu to determine the screen type and resolution. Then query the corresponding number. Each resolution is divided into 6-digit and 8-digit, with a total of 6 numbers. It is generally recommended to use 8-digit screen reference number first.

3 EDP screen is usually 30 pins with 0.5 spacing. The standard line of the screen tester can measure 80% EDP screen with 1920 * 1080 resolution and below, which is different from LVDS screen. The screen with 2K resolution or above and the screen line with standard configuration can not be tested normally needs to be made by hand, and the LCD screen needs to be provided at the same time. Generally, it is connected to ports a, C and D of the tester. When the screen is bright, but the screen is flashing or black, port B, C and D are used. If some manual lines do not have port C, only port B and D are needed. The standard line of EDP screen whose screen model starts with vvx can't be applied, so it must be done manually again. Au screen containing b116htn, b133htn, b140htn and b156htn can be normally displayed with B, C and D. Qimei's n133hse-ea3 / EB3 can be displayed normally only with B, C and D.

4. If a, C, D or B, C, D glass signal image display is normal but the backlight is not bright, it means that the screen does not have its own backlight boost module, and it needs to do the screen connecting line and external constant current board manually.

CH004231
€317.02

2K 4K EDP Screen Tester eDP signal universal testing instrument 74 Kinds test screen tools

ZOTEK ZT203 6000 Counts Pentype Digital Multimeter True RMS Auto Range DCAC Voltage Meter Voltmeter with Backlight

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

Description:

This is battery-powered, true RMS, auto-ranging, pen-type digital multimeter with 6000

counts backlight LCD display.

Five functional buttons instead of the traditional rotary switch enable one-hand operation.

This product is made of high quality material and durable, which can prevent breakage.

Features:

5 functional buttons: instead of the traditional rotary switch, 5 buttons can make you

measurements more convenient and efficient.

True RMS: The RMS/DC transform avoids the influence of voltage waveform distortion can test high accuracy.

LCD Display: 6000 counts digital LCD display offers large test rang as well as clear readings.

7 Test Modes: used to test DC & AC voltage, capacitance, resistance, frequency, continuity,

diode and NCV.

Humanized Design: it comes with auto power off, data hold, auto/manual range.

Specifications:

Material: Plastic

Display: LCD display with backlight

DC Voltage Range: 60mV/600mV/6V/60V/600V/1000V

AC Voltage Range: 60mV/600mV/6V/60V/600V/750V

Resistance Range: 600O/6kO/60kO/600kO/6MO/60MO

Capacitance Range: 9.999nF/99.99nF/999.9nF/9.999F/99.99F/999.9F/9.999mF

Frequency: 99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz

Diode: yes

Continuity: yes

NVC: yes

Maximum display: 6000

Automatic range/manual range: yes

True effective value: yes

Data retention: yes

Flashlight: yes

Low battery tip: yes

Automatic shutdown: yes

Relative value measurement: yes

Supply power: 2 x 1.5V AAA batteries (not included)

Item dimension:

Item Size: 20.2cm x 5.1cm x 3.4cm/7.6 x 2 x 1.3in

Item Weight: 114g/4oz

Package information:

Package Size: 23.2* 9 * 5.5cm / 9.1 * 3.5 * 2.7in

Package Weight: 267g/9.4oz

Gift box package

Package List:

1 x Digital Multimeter

1 x Pair of Test Leads

1 x Black soft case

1 x User Manual(English)

CH004292
€22.75

ZOTEK ZT203 6000 Counts Pen-type Digital Multimeter True RMS Auto Range DC/AC Voltage Meter Voltmeter with Backlight

2160842009 HD8730M

216-0842009 HD8730M

Part Number 216-0842009 Manufacturer AMD

BGA Alloy No Pb/Lead Free Date Code 1234

Package/Case 360 Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001251
€67.04

216-0842009 HD8730M

N15VGMSA2

N15V-GM-S-A2

Part Number N15V-GM-S-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 13+

Package/Case 1 PCS Description Brand new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001262
€24.62

N15V-GM-S-A2

FH82HM370 SR40B

FH82HM370 SR40B

Part Number SR408 Manufacturer INTEL

BGA Alloy No Pb/Lead Free Date Code 16+

Package/Case 1 PCS Description Brand new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001266
€62.36

FH82HM370 SR40B

QDFX350MTNA3

QD-FX-350MT-N-A3

Part Number QD-FX-350MT-N-A3 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 0952

Package/Case 600 PCS Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001277
€21.33

QD-FX-350MT-N-A3

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

More Similar Products

1 Pair 1000V 20A Universal Digital Multimeter Meter Probe Test Leads 3mm Pin Red + Black

Features :

100% brand new and high quality.

The anterior gold-plated design, in the test, the sensitivity of pens and higher and more accurate.

22mm Plug Insertion Depth.

Up to 20A / 1000V

Material: PVC and Alloy

Color: Black + Red

Package includeds :

1 x Pair of Digital Multimeter Meter Probe

CH004435
€2.70

1 Pair 1000V 20A Universal Digital Multimeter Multi Meter Test Lead Probe Wire Pen Cable L1Y

G73VZANA2

G73-VZA-N-A2

Part Number G73-VZA-N-A2 Manufacturer NVIDIA

BGA Alloy No Pb/Lead Free Date Code 1018

Package/Case 240 Description Original new

Technical Support

BGA CHIPSET OBSERVE PRECAUTIONS FOR HANDLING

BGA Chips is MOISTURE SENSITIVE DEVICES. Devices require baking, before mounting, Here is the general bake-out process, Lay the BAG on the tray, and put it in to a baking dry cabinet. Set the temperature and time as: 125C x 24 hours or 80C x 48 hours

Pay attention to the difference between

leaded (Pb) balls and lead free (No Pb) balls.

Lead-free/No Pb BGA chips:

245C-260C(Maximun)

Leaded/Pb BGA chips:

180C-205C(Maximun)

Sufficient Stock

CH001286
€24.62

G73-VZA-N-A2